4 configure the module via command line interface – Omnitron Systems Technology iConverter Network Management Module User Manual
Page 9
3.4
CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE
To configure, attach the NMM to a DB-9 serial (RS-232) equipped computer with terminal emulation
software such as HyperTerminal. Using a standard serial cable, connect the serial port of the PC and the
Serial Console Port of the NMM. This is a standard asynchronous DCE serial interface. The pin-outs are
illustrated below.
1
6
5
9
2
3
5
7
DB-9 Female
RD
TD
GND
RTS
Serial Connector Pin Outs
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window.
Set the PC’s serial port to the following:
Bits Per Second:
57,600
Stop Bits:
1
Data Bits:
8
Parity:
NONE
Hardware Flow Control:
NONE
Power the chassis containing the NMM and press <ENTER> to bring up a command line prompt on the
attached PC.
The module is configured with the following defaults:
IP
IP Address:
192.168.1.220
IP Subnet Mask:
255.255.255.0
Passwords
Serial:
No password assigned
FTP:
No password assigned
Telnet:
public
SNMPv1/v2c Communities
READ:
public
WRITE:
public
SNMPv3 Parameters
User 1 name (read only):
guest
User 2 name (read/write):
admin
User 1 Privacy pwd:
publicguest
User 1 Authen pwd:
publicguest
User 2 Privacy pwd:
privateadmin
User 2 Authen pwd:
privateadmin
Page 9