3.4.1.2

Setting IP Parameters as DHCP Client

To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The
Other Networking Features screen will appear.

Management Options

iConverter, Serial Agent

Network Management

1: Chassis and Module Management

2: Set Module Identifier

Management Module Preferences

3: IP and Control Preferences

4: SNMP Preferences

5: Abandon Preference Changes

6: Save Preference Changes

7: Restore to Factory Defaults

8: Restart Management Module

9: Other Networking Features

Management Module Maintenance

10: Firmware Update

11: Set Date/Time

IP Address = 192.168.1.220

Chassis Number = 1

Enter Choice, (H)elp, E(x)it > 9

Other Networking Features Screen

iConverter, Serial Agent

1:

Enable/Disable DHCP Client

Disabled

2:

Enable/Disable Keep Alive Trap

Disabled

3:

Keep Alive Trap interval (10-600 secs)

10

4:

Serial Baud Rate

57600 bps

5:

Enable/Disable Remote OAM

Enable

6:

Enable/Disable IP Protocol

Enable

7:

Enable/Disable VLAN Support

Disabled

8:

VLAN ID (0-4095)

2

9:

VLAN Priority (0-7)

7

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To enable DHCP client, select 1 at the Other Networking Features screen and follow the screen prompts
to enable DHCP.

To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.

3.4.1.3

Setting the Chassis Number and Name

A Chassis Name, or sysName, can be assigned to the NMM for identification to the SNMP management
software. The name can be any 1-32 character alphanumeric string.

The Chassis Number can remain as 1 (factory default) when the NMM is installed without another management
module (a media converter with integrated management such as the 10/100M) in the same chassis. When the
NMM is installed in the same chassis with another management module, they must all be set to the same Chassis
Number.

To set the Chassis Number, select 4 at the IP and Control Preferences screen, press and follow
the instructions to enter the chassis number.