beautypg.com

Access the nmm remotely – Omnitron Systems Technology iConverter Network Management Module User Manual

Page 17

background image

switch settings, then the module’s hardware settings take effect.

To set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press <ENTER>
and then follow the screen prompts to change the setting.

IP and Control Preferences Screen

iConverter, Serial Agent

1: Set IP

192.168.1.220

2: Set Subnet Mask

255.255.255.0

3: Set Gateway

192.168.1.1

4: Chassis Number

1

5: Chassis Name (also sysName)

NMM

6: Enable/Disable TELNET

Enabled

7: Enable/Disable FTP

Disabled

8: Enable/Disable Soft Switch Reload

Disabled

9: TELNET Password

*****

10: FTP Password

11: Serial Password

Enter Choice, Management Options Screen(0), (H)elp, E(x)it >

To save the new values, select 0 and press to return to the Management Options screen, then
select 6 and press to Save Preference Changes.

Page 17