beautypg.com

Maintenance, Door glass, Installing valve – Regency P48-2 User Manual

Page 44

background image

Regency

®

P48-2 Zero Clearance Direct Vent Gas Fireplace

44

CAUTION: Wear gloves when
removing damaged or broken
glass.

BAY GLASS REPLACEMENT

1) Remove the door from the unit and place on

a soft surface to prevent scratching.

2) Remove the nuts holding the glass clips in

place and remove.

3) Replace the glass. The glass must have

gasketing around it.

4) Reverse the previous steps, replace the glass

clips and fasten with the nuts but do not over
tighten, as this can break the glass.

5) Replace door on the stove and check the

seal.

MAINTENANCE

WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualifi ed service person.

DOOR GLASS

Your Regency

®

fi replace is supplied with high

temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.

CAUTION & WARNINGS:

* Do not clean when the glass is hot.
* The use of substitute glass will void all product

warranties.

* Care must be taken to avoid breakage of the

glass.

* Do not strike or abuse the glass.
* Do not operate this fi replace without the

glass front or with a cracked or broken glass
front.

* Wear gloves when removing damaged or

broken glass.

* Replacement of the glass panel(s) should be

done by a licensed or qualifi ed service per
son.

GLASS REPLACEMENT

In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency

®

dealer only.

Replacement glass is shipped already installed
into the door frame. Reinstall as per Glass Door
Installation in "Standard Flush Door" section.

INSTALLING VALVE

1) Attach the valve to the valve bracket with

the 4 (m5x8 metric) screws provided.

2) Reconnect the "gas out" fl are fi tting with an

11/16" wrench.

3) Reconnect the "gas out" fl are nut with a

13/16" wrench.

4) Install piezo ignitor push button assembly

and reconnect wire.

5) Reconnect the quick drop out thermocouple

nut with a 9mm wrench.

6) Reconnect the pilot tube nut with a 7/16"

wrench.

7) Scrape off the old gasket from the fl oor of the

fi rebox and from the valve tray assembly.

8) Install a new gasket and reinstall the valve

tray assembly.

Note: Failure to install a new gasket

may severely affect the appliance
performance.

9) Reinstall the 10 hold down screws.

10) Hook up the 2 TP and 2 TH wires to the

appropriate connections on the valve.

11) Reinstall the two bottom defl ectors and brick

panels.

12) Install burner and grate assembly.

13) Hook up the gas line and check for gas

leaks with a soap and water solution or a
gas leak detector. (Do not use open fl ame
for leak testing.)

14) Fire up the unit temporarily.

15) Check the manifold pressure.

16) Reinstall the logs and brick panels as

needed.

17) Close the door and replace the louvers.

18) Fire up the unit again and check for proper

fl ame appearance and glow on logs.