Installation, Fig. 6, Fig.3 – Regency P48-2 User Manual
Page 28: Fig.2, Installation of the dc sparker
Regency
®
P48-2 Zero Clearance Direct Vent Gas Fireplace
28
INSTALLATION
17) Reverse steps 4) to 1).
18) Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
19) Replace yellow "Natural Gas" label with
red "Propane" label
20) Check for gas leaks.
WARNING!
Do not overtighten the screw.
Recommended to
grip the wrench by the short side.
15) Verify that if the conversion is from NG to
LPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).
16) Re-assemble the black protection cap
(Fig. 6).
WARNING!
Also check that the pilot
and main burner injectors are
appropriate for the gas type.
LPG Configuration
Red o-ring visible
Fig.5
Fig. 6
21) Check inlet and outlet pressures.
22) Check operation of fl ame control.
23) Check for proper fl ame appearance and
glow on logs.
24) Locate the Piezo Ignitor situated at the
side of the valve.
12) Check that the screw is clean and if
necessary remove dirt.
13) Flip the screw (Fig. 3).
14) Using the Allen wrench as shown in
Fig.4, rotate the screw clockwise until
snug, do not overtighten.
Fig.3
Fig.4
Installation of the DC Sparker:
25) Remove the Piezo Ignitor by unscrewing the
nut at the back of the mounting bracket.
26) Disconnect the ignitor wire from the Piezo
Ignitor and connect it to the DC Sparker.
Piezo
Ignitor
Ignitor
Wire
Piezo
Ignitor
Ignitor
Wire
DC
Sparker
27) Connect the DC spark generator wires
to the SIT Valve with the screw, which is
provided in the kit.
11) Insert a 5/32” or 4mm Allen wrench into
the hexagonal key-way of the screw
(Fig. 2), rotate it counter-clockwise until
it is free and extract it.
Fig.2