beautypg.com

Installation, Fig. 6, Fig.3 – Regency P48-2 User Manual

Page 28: Fig.2, Installation of the dc sparker

background image

Regency

®

P48-2 Zero Clearance Direct Vent Gas Fireplace

28

INSTALLATION

17) Reverse steps 4) to 1).

18) Attach the label "This unit has been

converted to LPG" near or on top of the
serial # decal.

19) Replace yellow "Natural Gas" label with

red "Propane" label

20) Check for gas leaks.

WARNING!

Do not overtighten the screw.

Recommended to

grip the wrench by the short side.

15) Verify that if the conversion is from NG to

LPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).

16) Re-assemble the black protection cap

(Fig. 6).

WARNING!

Also check that the pilot

and main burner injectors are

appropriate for the gas type.

LPG Configuration

Red o-ring visible

Fig.5

Fig. 6

21) Check inlet and outlet pressures.

22) Check operation of fl ame control.

23) Check for proper fl ame appearance and

glow on logs.

24) Locate the Piezo Ignitor situated at the

side of the valve.

12) Check that the screw is clean and if

necessary remove dirt.

13) Flip the screw (Fig. 3).

14) Using the Allen wrench as shown in

Fig.4, rotate the screw clockwise until
snug, do not overtighten.

Fig.3

Fig.4

Installation of the DC Sparker:

25) Remove the Piezo Ignitor by unscrewing the

nut at the back of the mounting bracket.

26) Disconnect the ignitor wire from the Piezo

Ignitor and connect it to the DC Sparker.

Piezo

Ignitor

Ignitor

Wire

Piezo

Ignitor

Ignitor

Wire

DC

Sparker

27) Connect the DC spark generator wires

to the SIT Valve with the screw, which is
provided in the kit.

11) Insert a 5/32” or 4mm Allen wrench into

the hexagonal key-way of the screw
(Fig. 2), rotate it counter-clockwise until
it is free and extract it.

Fig.2