beautypg.com

Installation – Regency P48-2 User Manual

Page 29

background image

Regency

®

P48-2 Zero Clearance Direct Vent Gas Fireplace

29

INSTALLATION

28) Locate the ground lug at the receptical box,

left of the unit.

29) Connect one end of the supplied green

ground wire to the lug with the nut and
washer from the kit.

30) Install the 1/2" bushing to the heat

shield.

Ground

wire from

kit

32) Plug the DC spark generator wires to the

DC Sparker.

33) Connect the ground wire to the DC Sparker

mounting bracket.

35) Mount the heat shield to the DC Sparker.

Secure into place with the velcro, which is
provided in the kit.

Heat Shield

31) Run the other end of the ground wire and

DC spark generator wires through the
bushing on the heat shield.

37) Tie up the loose wire with the wire clip.

Chain

36) Find a location which is not too hot and

is easy to reach for changing the battery.
Note: It should be kept away from the
chain.

34) Install the supplied battery into the DC

Sparker Box by opening the battery
compartment.

NOTE: The battery in the DC Sparker Box

will need to be replaced annually.

Battery

Compartment