beautypg.com

Maintenance, Installing valve – Regency SEE THRU P121-NG User Manual

Page 32

background image

Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

32

12) Lift the entire assembly out.

8) Remove the Side Base Brick Panels and

finally the Long Base Brick Panels.

MAINTENANCE

Remove Left & Right Side Base

Brick Panels

Remove the 2 Long Base Brick Panels

9) Disconnect the inlet gas line.

10) Disconnect the 2 TP wires and the 2 TH

wires from the valve.

11) Remove the 16 Phillips head screws secur-

ing the valve tray.

13) Undo the pilot tube from the valve with a

7/16" spanner.

14) Undo the quick drop out thermocouple nut

on the valve with a 9mm (metric) spanner.

15) Remove the Piezo igniter wire and push

button assembly.

16) Undo the "gas out" flare nut with a 13/16"

spanner.

17) Undo the "gas out" flare fitting with an

11/16" spanner.

18) Remove the 6 Phillips head screws from the

sides of the valve bracket and remove

valve.

Hint:

If you are using black pipe, ensure

that there is a union by the valve,

otherwise removal will be almost

impossible.

INSTALLING VALVE

1) Attach the valve to the valve bracket with

the 6 (m5x8 metric) screws provided.

2) Reconnect the "gas out" flare fitting with an

11/16" spanner.

3) Reconnect the "gas out" flare nut with a 13/

16" spanner.

4) Install piezo ignitor push button assembly

and reconnect wire.

5) Reconnect the quick drop out thermocouple

nut with a 9mm spanner.

6) Reconnect the pilot tube nut with a 7/16"

spanner.

7) Scrape off the old gasket from the floor of

the firebox and from the valve tray assem-

bly.

8) Install a new gasket and reinstall the valve

tray assembly.

Note: Failure to install a new gasket may

severely affect the appliance perform-

ance.

9) Reinstall the 16 hold down screws.

10) Hook up the 2 TP and 2 TH wires to the

appropriate connections on the valve.

11) Reinstall the Burner Assembly.

13) Hook up the gas line and check for gas leaks

with a soap and water solution or a gas leak

detector. (Do not use open flame for leak

testing.)

14) Fire up the unit temporarily

15) Check the manifold pressure.

16) Reinstall the logs, grate and brick panels as

needed.

17) Reinstall the glass doors.

18) Fire up the unit again and check for proper

flame appearance.

This manual is related to the following products: