Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

28

WIRING DIAGRAM

Caution: Ensure that the wires do

not touch any hot surfaces and are

away from sharp edges.

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring er-

rors can cause improper and

dangerous operation.

INSTALLATION

No electrical power supply is required for the

gas control to operate.

(Do not cut the ground terminal off under

any circumstances.)

Terminal Block Location

Terminal Block

Remove cover to

access Terminal

Block

FROM

POWER LIVE POWER NEUTRAL

WHITE

TERMINAL

BLOCK

FAN 1

1

2

FAN 2

~

BLACK

GROUND

(WIRE SUPPLY & INSTALL BY OTHERS)

910-802 BLACK

CONVECTION AIR
TEMPERATURE SWITCH

(THERMO DISC - NORMALLY OPEN)

~

ON-OFF SWITCH
(910-138) BLACK

910-610 BLACK

Lockwasher

Nut

#8 Ground Lug

(for mobile home)

Star washer

Ground Wire

Grounding Lug Detail

Yellow

Orange

Burner

ON
OFF

DC Spark

Box

Ground

To Thermocouple IN

Pilot

Assembly

H

I

LO

OFF

ON

P

IL

O

T

Gas

Pilot

Thermopile

Thermocouple

Electrode

Remote Transmitter

(Optional)

ON

OFF

Regency

Remote Receiver

or Thermostat

(Millivolt) (Optional)

Brown

White

"S.I.T" Valve

(To THTP)

(To TH)

Gas
In

This manual is related to the following products: