Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

27

Option 1:

REMOTE CONTROL

Can be used with Option 2 or 3

but not both.

Use the Regency Remote Control Kit approved

for this unit. Use of other systems may void your

warranty.

The remote control kit comes with a hand held

transmitter, a receiver and a wall mounting

plate.

1) Choose a convenient location on the wall to

install the receiver and the receptacle box

(protection from extreme heat is very im-

portant). Run wires from the fireplace to

that location. Use the Thermostat Wire Ta-

ble.

2) Connect the two wires to the gas valve.

See diagram below.

Option 2:

WALL SWITCH

Can be used with Option 1 or 3

but not both.

1) Run the supplied 4.5m of wire through the

back gas inlet opening. Be careful not to

damage wire.

Note: We recommend a maximum of

4.5m of wire but if you wish to go

with a longer run, use the Thermo-

stat Wire Table.

2) Connect the wire to the supplied wall switch

and install into the receptacle box.

CAUTION

Do not connect millivolt

wall switch wire to a 240V wire.

CAUTION

Do not connect millivolt remote

control wires to a 240V wire.

14 GA.

16 GA.

18 GA.

20 GA.

22 GA.

15.0 M.

10.0 M.

6.0 M.

3.6 M.

2.7 M.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Thermostat Wire Table

Option 3:

WALL THERMOSTAT

Can be used with Option 1 or 2

but not both.

A wall thermostat may be installed if desired,

connect the wires as per the wiring diagram.

Use the table below to determine the maximum

wire length.

Note: Preferable if the thermostat is in-

stalled on an interior wall.

Regency offers an optional programmable ther-

mostat but any 250-750 millivolt rated non-

anticipator type thermostat that is CSA, ULC or

UL approved may be used.

CAUTION

Do not connect millivolt

wall thermostat wires

to a 240V wire.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.

Install the receiver and its cover in the wall.

Switch the remote receiver to "remote"

mode. The remote control is now ready for

operation.

INSTALLATION