Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace

16

INSTALLATION

Diagram 3

Horizontal Flueing with Two (2) 90

o

Elbows

Option

V

H + H1

A)

1' (305mm) Minimum

2' (610mm) Maximum

B)

2' (610mm) Minimum

5' (1.5m) Maximum

C)

3' (914mm) Minimum

8' (2.4m) Maximum

D)

4' (1.22m) Minimum

11' (3.35m) Maximum

E)

5' (1.5m) Minimum

14' (4.27m) Maximum

F)

6' (1.86m) Minimum

15' (4.5m) Maximum

Horizontal Flueing with Two (2) 90

o

Elbows

Option

V

H

H + H1

A)

1' (305mm) Min. 1' (305mm) Max. 3' (914mm) Max.

B)

2' (610mm) Min. 3' (0.91m) Max. 6' (1.86m) Max.

C)

3' (914mm) Min. 5' (1.5m) Max.

9' (2.7m) Max.

D)

5' (1.5m) Min.

8' (2.4m) Max.

12' (3.6m) Max.

Horizontal Flueing with Three (3) 90

o

Elbows

Horizontal Flueing with Three (3) 90

o

Elbows

Diagram 5

Diagram 4

Diagram 6

With the above options, maximum total pipe length if 37 feet with

minimum of 6 feet total vertical and maximum 15 feet total horizontal.

Please note minimum 1 foot between 90

o

elbows is required.

Option

V

H

H + H1 + H2

A)

2' (610mm) Min. 1' (305mm) Max. 3' (914mm) Max.

B)

3' (914mm) Min. 3' (914mm) Max. 6' (1.86m) Max.

C)

4' (1.22mm) Min. 5' (1.5m) Max.

9' (2.7m) Max.

D)

5' (1.5m) Min.

7' (2.13m) Max. 12' (3.6m) Max.

With the above options, maximum total pipe length if 37 feet with

minimum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90

o

elbows is required.

With the above options, maximum total pipe length if 37 feet with

minimum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90

o

elbows is required.

Option

V + V1

H + H1

A)

2' (610mm) Minimum

3' (914mm) Maximum

B)

3' (914mm) Minimum

6' (1.86m) Maximum

C)

4' (1.22m) Minimum

9' (2.7m) Maximum

D)

5' (1.5m) Minimum

12' (3.6m) Maximum

With the above options, maximum total pipe length if 37 feet with

minimum of 5 feet total vertical and maximum 12 feet total horizontal.

Please note minimum 1 foot between 90

o

elbows is required.