beautypg.com

Installation, Installation checklist, Important message save these instructions – Regency G36D User Manual

Page 5: Before you start, General safety information

background image

UltraGlow

®

G36D Zero Clearance Direct Vent Gas Fireplace

5

INSTALLATION

CHECKLIST

1) Check all clearances to combustibles. Refer

to the following sections:

a) Locating Your Gas Stove

b) Clearances

c) Mantel Leg Clearances

d) Combustible Mantels

e) Framing and Finishing

f) Hearth Requirement

2) Assemble Top Standoffs and Top Facing

Support and Side Nailing Strips, Refer to the

"Unit Aseembly Prior to Installation" section.

(NOTE: must be done before installing unit

into fi replace.)

3) Install vent. Refer to the "Venting"

section.

4) Install standard and optional features.

Refer to the following sections where

applicable:

a. Log Set Installation

b. Standard Flush Door

c. Option 1: Remote Control

d. Option 2: Wall Switch

e. Option 3: Wall Thermostat

f. Installating the Optional Fan

9) Final check.

Before leaving this unit with the customer,

the installer must ensure that the appliance is

fi ring correctly and

operation fully explained

to customer.

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The G36D-NG1 or G36D-LP1 Direct Vent
Fireplace must be installed in accordance
with these instructions. Carefully read all the
instructions in this manual fi rst. Consult the
"authority having jurisdiction" to determine the
need for a permit prior to starting the installation.
It is the responsibility of the installer to ensure
this fi replace is installed in compliance with
manufacturer's instructions and all applicable
codes.

BEFORE YOU START

Safe installation and operation of this appliance

requires common sense, however, we are

required by the Canadian Safety Standards

GENERAL SAFETY

INFORMATION

1) The appliance installation must conform

with local codes or, in the absence of local

codes, with the current Canadian or National

Gas Codes, CAN1-B149 or ANSI Z223.1

Installation Codes.

2) The appliance when installed, must be

electrically grounded in accordance with

local codes, or in the absence of local codes

with the current National Electrical Code,

ANSI/NFPA 70 or CSA C22.1 Canadian

Electrical Code.

3) See general construction and assembly

instructions. The appliance and vent should

be enclosed.

4) This appliance must be connected to the

specifi ed vent and termination cap to the

outside of the building envelope. Never vent

to another room or inside a building. Make

sure that the vent is fi tted as per Venting

instructions.

5) Inspect the venting system annually for

blockage and any signs of deterioration.

6) Venting terminals shall not be recessed into

a wall or siding.

7) Any safety glass removed for servicing

must be replaced prior to operating the

appliance.

8) To prevent injury, do not allow anyone who

is unfamiliar with the operation to use the

fi replace.

9) Wear gloves and safety glasses for protection

while doing required maintenance.

10) Be aware of electrical wiring locations in

walls and ceilings when cutting holes for

termination.

11) Under no circumstances should this

appliance be modifi ed. Parts that have to

be removed for servicing should be replaced

prior to operating this appliance.

12) Installation and any repairs to this appliance

should be done by a qualifi ed service person.

A professional service person should be

called to inspect this appliance annually.

Make it a practice to have all of your gas

appliances checked annually.

13) Do not slam shut or strike the glass door.

14) Under no circumstances should any solid

fuels (wood, paper, cardboard, coal, etc.)

be used in this appliance.

15) The appliance area must be kept clear and

free of combustible materials, (gases and

other fl ammable vapours and liquids).

INSTALLATION AND REPAIR SHOULD

BE DONE BY A QUALIFIED SERVICE

PERSON. THE APPLIANCE SHOULD

BE INSPECTED BEFORE USE

AND AT LEAST ANNUALLY BY A

PROFESSIONAL SERVICE PERSON.

MORE FREQUENT CLEANING MAY

BE REQUIRED DUE TO EXCESSIVE

LINT FROM CARPETING, BEDDING

MATERIAL, ETC. IT IS IMPERATIVE

THAT CONTROL COMPARTMENTS,

BURNERS AND CIRCULATING AIR

PASSAGEWAYS OF THE APPLIANCE

BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE

APPLIANCE SHOULD BE LOCATED

OUT OF TRAFFIC AND AWAY FROM

FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS

APPLIANCE CORRECTLY WILL VOID

YOUR WARRANTY AND MAY CAUSE

A SERIOUS HOUSE FIRE.

CHILDREN AND ADULTS SHOULD

BE ALERTED TO THE HAZARDS OF

HIGH SURFACE TEMPERATURES,

ESPECIALLY THE FIREPLACE GLASS,

AND SHOULD STAY AWAY TO AVOID

BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE

CAREFULLY SUPERVISED WHEN

THEY ARE IN THE SAME ROOM AS

THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE

MATERIAL SHOULD NOT BE PLACED

ON OR NEAR THE APPLI

ANCE.

Emissions from burning wood or gas could

contain chemicals known to the State of

California to cause cancer, birth defects or

other reproductive harm.