Installation, Rigid pipe venting systems, Horizontal or vertical terminations – Regency G36D User Manual

Page 13

background image

UltraGlow

®

G36D Zero Clearance Direct Vent Gas Fireplace

13

Rigid Pipe Adaptor

(Part# 510-994)

Pipe Length

Vertical

Terminal

Storm Collar

(Part # 953)

Flashing

943 or 943S

Ceiling Firestop

(Part # 963)

24" Pipe

Length

Adj.Pipe Length

11" - 14-5/8"

90 Elbow

o

Horizontal

Termination Cap

(Part# 946-523/P)

Wall Thimble

(Part # 942)

Vinyl Siding

Standoff (Optional)

(Part #950)

INSTALLATION

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

The minimum components required for a basic horizontal termination

are:

1 Horizontal Termination Cap

1 90

o

Elbow

1 Rigid Pipe Adaptor

1 Wall Thimble

1 Length of pipe to suit wall thickness (see chart)

Wall thickness is measured from the back standoffs to the inside mounting

surface of termination cap. For siding other than vinyl furring strips may

be used, instead of the vinyl siding standoff, to create a level surface to

mount the vent terminal. The Terminal must not be recessed into siding.

Measure the wall thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used with vinyl siding),

measure to outside surface of wall without siding and add 2 inches.

Alternate

Horizontal Ter-

mination Caps

When using Rigid Vent piping other than

Simpson Dura-Vent, 3 screws must be

used to secure rigid pipe to adaptor.

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent GS,

American Metal Products Ameri Vent Direct Vent and Selkirk Direct-Temp. AstroCap

TM

is the proprietary trademark of FPI Fireplace Products International

Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

This product has been evaluated by Intertek

for using a Rigid Pipe Adaptor in conjunction

with Dura-Vent Direct Vent GS, Selkirk Direct-

Temp, Ameri Vent Direct venting and Security

Secure Vent systems. Use of these systems with

the Rigid Pipe adaptor is deemed acceptable

and does not affect the Intertek WHI listing of

components.

WARNING:

Do not combine venting components from

different venting systems.

However use of the the AstroCap

TM

and FPI

Riser is acceptable with all systems.

Flat Wall Installation

Wall Thickness

(inches)

Vent Length Required

(inches)

4" - 5-1/2"

6"

7" - 8-1/2"

9"

10" - 1-1/2"

12"

9" - 14-1/2"

11" - 14-5/8" Adj. Pipe

15" - 23-1/2"

17" - 24" Adj.

Corner Installation

Wall Thickness

(inches)

Vent Length Required

(inches)

3-1/4" - 6-3/4"

11" - 14-5/8" Adj. Pipe

7-3/4" - 16-1/4"

17" - 24" Adj. Pipe

7-1/4" - 8-3/4"

6" + 12"

9" + 9"

4-1/4" - 5-3/4"

6" + 9"