Installation, Exterior vent termination locations – Regency G36D User Manual
Page 10
UltraGlow
®
G36D Zero Clearance Direct Vent Gas Fireplace
®
®
10
INSTALLATION
EXTERIOR VENT TERMINATION LOCATIONS
.
B
B
B
B
A
C
V
V
V
V
V
V
V
A
A
V
Fixed
Fixed
Openable
Closed
Closed
Openabl
e
N
L
B
E
B
M
D
F
K
H
j
V
ertical
Termination
V
V
ent
terminal
Area
where
terminal
is
not
permited
A
Air
supply
outlet
24"
V
A
G
Inside
corner
det
ail
V
24"
18"
V
ertical
Termination
B=
Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)
C=
Clearance to permanently closed window *(min. 12"/30cm)
D=
Vertical
clearance
to
ventilated
soffi
t
located
above
the
terminal
within
a
horizontal
distance
of
(24"/60cm)
from
the
centerline
of
the
terminal
(min.
18"/46cm)
check
with
local code.
E=
Clearance to unventilated soffi
t (min. 15"/38cm)
F=
Clearance
to
outside
corner:
with
AstroCap
T
ermination
Cap
(min.
6"/15cm),
with
Dura-V
ent
Termination Cap (14"/36cm)
G=
Clearance
to
inside
corner:
with
AstroCap
T
ermination
Cap
(min.
6"/15cm),
with
Dura-
Vent
Termination Cap (12"/30cm)
H=
Not
to
be
installed
above
a
meter/regulator
assembly
within
(3'/90cm)
horizontally
from the centerline of the regulator
.
J=
Clearance to service regulator vent outlet *(min. 36"/90cm)
K=
Clearance
to
non-mechanical
air
supply
inlet
to
building
or
the
combustion
air
inlet
to
any other appliance *(12"/30cm) #(9"/23cm)
L=
Clearance to a mechanical air supply inlet *(min. 72"/1.8m)
#3' (91cm) above if with in 10' (3m) horizontally
.
M=
Clearance
above
paved
sidewalk
or
a
paved
driveway
located
on
public
property
*(min. 84"/2.1m)
N=
Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)
Note: - A
vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
- Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl
oor
.
- If the vent termination is accessible, a certifi
ed guard shall be installed.
* As specifi
ed in CGA
B149 Installation Code. Note: Local codes or regulations may require dif
ferent clearances.
# In accordance with the current
ANSI Z223.1/NFP
A 54 ,National Fuel Gas Code.