UltraGlow

®

G36D Zero Clearance Direct Vent Gas Fireplace

®

®

10

INSTALLATION

EXTERIOR VENT TERMINATION LOCATIONS

.

B

B

B

B

A

C

V

V

V

V

V

V

V

A

A

V

Fixed

Fixed

Openable

Closed

Closed

Openabl

e

N

L

B

E

B

M

D

F

K

H

j

V

ertical

Termination

V

V

ent

terminal

Area

where

terminal

is

not

permited

A

Air

supply

outlet

24"

V

A

G

Inside

corner

det

ail

V

24"

18"

V

ertical

Termination

B=

Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)

C=

Clearance to permanently closed window *(min. 12"/30cm)

D=

Vertical

clearance

to

ventilated

soffi

t

located

above

the

terminal

within

a

horizontal

distance

of

(24"/60cm)

from

the

centerline

of

the

terminal

(min.

18"/46cm)

check

with

local code.

E=

Clearance to unventilated soffi

t (min. 15"/38cm)

F=

Clearance

to

outside

corner:

with

AstroCap

T

ermination

Cap

(min.

6"/15cm),

with

Dura-V

ent

Termination Cap (14"/36cm)

G=

Clearance

to

inside

corner:

with

AstroCap

T

ermination

Cap

(min.

6"/15cm),

with

Dura-

Vent

Termination Cap (12"/30cm)

H=

Not

to

be

installed

above

a

meter/regulator

assembly

within

(3'/90cm)

horizontally

from the centerline of the regulator

.

J=

Clearance to service regulator vent outlet *(min. 36"/90cm)

K=

Clearance

to

non-mechanical

air

supply

inlet

to

building

or

the

combustion

air

inlet

to

any other appliance *(12"/30cm) #(9"/23cm)

L=

Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

#3' (91cm) above if with in 10' (3m) horizontally

.

M=

Clearance

above

paved

sidewalk

or

a

paved

driveway

located

on

public

property

*(min. 84"/2.1m)

N=

Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)

Note: - A

vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

- Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl

oor

.

- If the vent termination is accessible, a certifi

ed guard shall be installed.

* As specifi

ed in CGA

B149 Installation Code. Note: Local codes or regulations may require dif

ferent clearances.

# In accordance with the current

ANSI Z223.1/NFP

A 54 ,National Fuel Gas Code.