UltraGlow

®

G36D Zero Clearance Direct Vent Gas Fireplace

31

Thermostat Wire Table

Option 3:

WALL THERMOSTAT

A wall thermostat may be installed if desired,

connect the wires as per the wiring diagram.

Use the table below to determine the maximum

wire length.

Note: Preferable if the thermostat is installed

on an interior wall.

UltraGlow

®

offers an optional programmable

thermostat or basic wall thermostat but any

250-750 millivolt rated non-anticipator type

thermostat that is CSA, ULC or UL approved

may be used.

CAUTION

Do not connect millivolt

wall thermostat wires

to a 120V wire.

INSTALLATION

Option 1:

REMOTE CONTROL

Use the UltraGlow

®

Use the UltraGlow

Use the UltraGlow Remote Control Kit approved

®

®

for this unit. Use of other systems may void

your warranty.

The remote control kit comes with a hand held

transmitter, a receiver and a wall mounting

plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle

box (protection from extreme heat is very

important). Run wires from the fi replace

to that location. Use the Thermostat Wire

Table.

2) Connect the two wires to the gas valve. See

diagram below.

Option 2:

WALL SWITCH

1) Run the wire through the right or left side inlet

opening. Be careful not to damage wire.

Note: We recommend a maximum of 15'

of wire but if you wish to go with a

longer run, use the Thermostat Wire

Table.

2) Connect the wire to the wall switch and install

into the receptacle box.

CAUTION

Do not connect millivolt

wall switch wire to a 120V wire.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.

Install the receiver and its cover in the wall.

Switch the remote receiver to "remote"

mode. The remote control is now ready for

operation.

CAUTION

Do not connect millivolt remote

control wires to a 120V wire.

14 GA.

16 GA.

18 GA.

20 GA.

22 GA.

50 Ft.

32 Ft.

20 Ft.

12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Wire Size Max. Length