beautypg.com

Installation – Regency G36D User Manual

Page 26

background image

UltraGlow

®

G36D Zero Clearance Direct Vent Gas Fireplace

®

®

26

28) Install the 1/2" bushing to the heat

shield.

30) Plug the DC spark generator wires to the

DC Sparker.

31) Connect the ground wire to the DC

Sparker mounting bracket.

32) Mount the heat shield to the DC Sparker.

Secure into place with the velcro, which
is provided in the kit.

Heat Shield

29) Run the other end of the ground wire

and DC spark generator wires through
the bushing on the heat shield.

34) Tie up the loose wire with the wire clip.

Chain

33) Find a location which is not too hot and

is easy to reach for changing the battery.
Note: It should be kept away from the
chain.

35) Check for gas leaks.

36) Check inlet and outlet pressures.

37) Check operation of fl ame control.

38) Check for proper fl ame appearance and

glow on logs.

INSTALLATION