beautypg.com

Installation, Installing the optional fan – Regency G36D User Manual

Page 33

background image

UltraGlow

®

G36D Zero Clearance Direct Vent Gas Fireplace

33

120 Volt AC power is needed for the fan switch

and blower. A three wire power cord is provided

to be plugged into the receptacle.

Unit must be grounded at all times. Do

not cut the ground terminal off under any

circumstances.

1) Shut the power off.

2) Open the bottom louver door.

3) Slide the fan in towards the rear of the unit

and slip it over the two mounting studs.

Ensure that the fan blades do not rub

against the valve tubing.

Optional: If you require extra space to slide the fan to the back, the left spring can be unhooked

from the bracket.

Note: A 120 Volt AC power cord can be

installed at rough-in stage so that

the power is available. A three wire

power cord can be used.

5) If the left spring was unhooked in step 3),

hook it back into the bracket. Take care not

to clip any wires. Attach the adhesive backed

wire holder clip (Part #910-199) onto the

stove base.

INSTALLATION

INSTALLING THE OPTIONAL FAN

4) Plug the fan to the receptacle as shown in

the wiring diagram below.

To Remove the Fan

1) Shut the power off.

2) Reverse the above instructions.

Note: The bearings are lubricated for life.

Do not lubricate them. Make sure

you vacuum the fan area on a regular

basis.