G36D Zero Clearance Direct Vent Gas Fireplace

23

INSTALLATION

GAS PIPE PRESSURE

TESTING

The appliance must be isolated from the gas

supply piping system by closing its individual

manual shut-off valve during any pressure

testing of the gas supply piping system at test

pressures equal to or less than 1/2 psig. (3.45

kPa). Disconnect piping from valve at pressures

over 1/2 psig.

HIGH ELEVATION

This unit is approved in Canada for altitude 0

to 4500 ft. (CAN1 2.17-M91) with the orifi ce

supplied.

GAS LINE

INSTALLATION

The gas line can be brought through either the

right or the left side of the appliance. The gas

valve is situated on the right hand side of the

unit and the gas inlet is on the right hand side

of the valve.

Note: If the gas line is being installed from

the left side, be sure to leave room to

accommodate servicing of the fan.

The gas line connection may be made of rigid

pipe, copper pipe or an approved fl ex connector.

(If you are using rigid pipe, ensure that the valve

can be removed for servicing.) Since some

municipalities have additional local codes it is

Incorrect fl ame pattern will have small,

probably yellow fl ames, not coming into

proper contact with the rear burner or

thermopile or thermocouple.

always best to consult with your local authorities

and the CAN/CGA B149 installation code.

For USA installations follow local codes and/or

the current National Fuel Gas Code, ANSI

Z223.1.

When using copper or fl ex connectors use only

approved fi ttings. Always provide a union so

that gas lines can be easily disconnected for

servicing. Flare nuts for copper lines and fl ex

connectors are usually considered to meet this

requirement.

Important: Always check for gas leaks with a

soap and water solution or gas leak detector.

Do not use open fl ame for leak testing.

PILOT ADJUSTMENT

Periodically check the pilot fl ames. Correct

fl ame pattern has three strong blue fl ames:

1 fl owing around the thermopile, 1 around

the thermocouple and 1 fl owing across the

burner (it does not have to be touching the

burner).

Note: If you have an incorrect fl ame pattern,

contact your Regency

®

dealer for

further instructions.

The manifold pressure is controlled by a

regulator built into the gas control, and should

be checked at the pressure test point.

Note: To properly check gas pressure, both

inlet and manifold pressures should

be checked using the valve pressure

ports on the valve.

1) Make sure the valve is in the "OFF"

position.

2) Loosen the "IN" and/or "OUT" pressure

tap(s), turning counterclockwise with a

1/8" wide fl at screwdriver.

3) Attach manometer to "IN" and/or "OUT"

pressure tap(s) using a 5/16" ID hose.

4) Light the pilot and turn the valve to "ON"

position.

5) The pressure check should be carried out

with the unit burning and the setting should

be within the limits specifi ed on the safety

label.

6) When fi nished reading manometer, turn

off the gas valve, disconnect the hose and

tighten the screw (clockwise) with a 1/8"

fl at screwdriver. Note: Screw should be

snug, but do not over tighten.

snug, but do not over tighten.

S.I.T. VALVE DESCRIPTION

1) Gas on/off knob

2) Manual high/low adjustment

3) Pilot Adjustment

4) Thermocouple Connection - option

5) Outlet Pressure Tap

6) Inlet Pressure Tap

7) Pilot Outlet

8) Main Gas Outlet

9) Alternative TC Connection

Alternative TC Connection

Alternative TC Connection

Point

G36D-NG1 System Data

For 0 to 4500 feet altitude

Burner Inlet Orifi ce Sizes: #42

Max. Input Rating 26,000 Btu/h

Min. Input Rating 13,100 Btu/h

Supply Pressure

min.5.0" w.c.

Manifold Pressure

(High)

3.8"+/- 0.2"w.c.

Log Set: Ceramic fi bre, 7 per set.

Vent System: Simpson Dura-Vent Direct

Vent System or UltraGlow

®

Direct

®

®

Vent System (Flex)

G36D-LP1 System Data

For 0 to 4500 feet altitude

Burner Inlet Orifi ce Sizes: #53

Max. Input Rating 26,000 Btu/h

Min. Input Rating 13,800 Btu/h

Supply Pressure

min.12.0" w.c.

Manifold Pressure

(High)

11"+/- 0.2" w.c.

Log Set: Ceramic fi bre, 7 per set.

Vent System: Simpson Dura-Vent Direct

Vent System or UltraGlow® Direct

Vent System (Flex)