beautypg.com

7) connecting 144-pin 0.5-mm-pitch foot pattern, Caution – Renesas Emulation Pod for M16C/80 Group MCUs M30803T-RPD-E User Manual

Page 45

background image

( 43 / 74 )

(7) Connecting 144-pin 0.5-mm-pitch Foot Pattern

Figure 3.18 shows how to connect the emulation pod probe to the 144-pin 0.5-mm-pitch foot pattern
on the target system with the FLX-144NSD (not included), and here following is its procedure.

(1) Attach the NQPACK144SD (NQPACK, hereafter) included with the FLX-144NSD to the

target system.

(2) Attach the YQPACK144SD (YQPACK, hereafter) included with the FLX-144NSD to the

NQPACK, matching three holes of NQPACK and YQPACK.

(3) Insert the YQ-GUIDE's included with the YQPACK to the YQPACK, using the screwdriver

included with the NQPACK.

(4) Attach the FLX160-PRB to the FLX-144NSD.
(5) Attach the FLX-144NSD to the YQSOCKET144SDF.

Figure 3.18 Connecting emulation pod probe and 144-pin 0.5-mm-pitch foot pattern

CAUTION

Notes on Connecting the Target System:

• Take care not to attach the converter board in a wrong direction. It may cause a fatal

damage to the emulation pod.

• The small connectors of FLX-144NSD are guaranteed for only 50 insertion/removal

iterations.