1 removing the upper cover, Chapter 3. setting up, Caution – Renesas Emulation Pod for M16C/80 Group MCUs M30803T-RPD-E User Manual
Page 26: When removing the upper cover
( 24 / 74 )
Chapter 3. Setting Up
To use this emulation pod with your application system, it is necessary to set as follows. Set the
following after removing the upper cover.
• Change the oscillation frequency.
• Set the X
CIN
and X
COUT
pins for the target system.
• Set the signals such as HOLD/RDY to control the external device.
• Install the A-D conversion bypass capacitor.
3.1 Removing the Upper Cover
The procedure of removing the upper cover is shown below.
(1) Remove the four screws of both sides of this product and lift off the upper cover (see Figure 3.1).
(2) Set the jumper switches.
(3) Replace the upper cover and secure the four screws.
Figure 3.1 Removing the upper cover
CAUTION
When Removing the Upper Cover:
• Always shut OFF power when removing the upper cover or setting the switches.
• Do not touch the connector pins of the emulator main unit and the target MCU
connector pins. Static electricity may damage the internal circuits.