CHAPTER 2 INSTALLATION

– 45 –

NWA-008869-001 Rev.1.0

atch2001.fm

SW0
(Piano Key SW)

1

NOTE 3

ON

Source clock signal from network is
sent to the PLO0 input on MP card.

Source clock signal from network is not
sent to the PLO0 input on MP card.

2

NOTE 3

ON

Source clock signal from network is
sent to the PLO1 input on MP card.

Source clock signal from network is not
sent to the PLO1 input on MP card.

3

NOTE 4

ON

Remote loopback

For normal operation

4

NOTE 4

ON

Local loopback (AIS send)

For normal operation

5

NOTE 4

Set equalizer according to the cable
length between the PBX and the C.O.
or CSU.
• For DS-1 (SW1-3 ON)

• For DSX-1/Hong Kong/Taiwan

(SW1-3 OFF)

OFF

6

NOTE 4

OFF

7

NOTE 4

OFF

8

Not used

Continued on next page

SWITCH NAME

SWITCH

NUMBER

SETTING

POSITION

FUNCTION

CHECK

OFF

ON

5

6

7

8

1

2

3

4

OFF

OFF

OFF

OFF

ON

SW0-5 SW0-6 SW0-7 CABLE LENGTH TO CSU (0.5

φ)

ON

ON

ON

1199-1758 m (3930-5764 ft.)

OFF ON

ON

599-1199 m (1965-3930 ft.)

ON

OFF ON

0-599 m (0-1965 ft.)

OFF OFF ON

Not used

OFF OFF OFF Signal is not sent

SW0-5 SW0-6 SW0-7 CABLE LENGTH TO CSU (0.65

φ)

ON

ON

ON

0-40 m (0-131.2 ft.)

ON

ON

OFF 40-80 m (131.2-262.5 ft.)

ON

OFF ON

80-120 m (262.5-394 ft.)

ON

OFF OFF 120-160 m (394-525 ft.)

OFF ON

ON

160-200 m (525-656 ft.)

OFF OFF OFF Signal is not sent

ON

ON

OFF