Inspecting the interior of server – Nortel Networks Server 600r User Manual

Page 24

background image

24

Chapter 3 Preparing for installation

Inspecting the interior of server

Introduction

To inspect the interior of your 600r server, you must remove the server cover.

Note: If the server is powered down, proceed with the next step. If
the server if powered up, see the chapter, "Starting up and shutting
down the CallPilot server", in Installation and Configuration Task List
(NN44200-306) for proper shutdown procedures before you remove
the server cover.

To remove the server cover

Step

Action

1

Attach the ESD strap to your wrist.

2

While holding in the blue button at the top of the chassis, slide the
top cover back until it stops.

3

Lift the cover straight up to remove it from the platform.

4

Ensure the CallPilot PCI riser card is secure.

5

Inspect the interior for any cables that are not seated properly.

6

Take note of any physical signs of damage. For example, check for
loose piece parts and screws in the corners of the chassis.

7

If you notice damage to any of the parts in your server, contact your
Nortel representative immediately.

—End—

To replace the server cover

When you finish inspecting the interior of your server, replace the server
cover.

Step

Action

1

Attach the ESD strap to your wrist and attach the other end to a
known grounded connection.

2

Place the cover on the server and align the cover with the chassis
tab guides.

3

Slide the top cover back until it stops.

—End—

Nortel CallPilot

600r Server Hardware Installation

NN44200-307

01.03

Standard

5.0

14 May 2008

Copyright © 2007-2008, Nortel Networks

.