Inspecting the interior of server – Nortel Networks Server 600r User Manual
Page 24
24
Chapter 3 Preparing for installation
Inspecting the interior of server
Introduction
To inspect the interior of your 600r server, you must remove the server cover.
Note: If the server is powered down, proceed with the next step. If
the server if powered up, see the chapter, "Starting up and shutting
down the CallPilot server", in Installation and Configuration Task List
(NN44200-306) for proper shutdown procedures before you remove
the server cover.
To remove the server cover
Step
Action
1
Attach the ESD strap to your wrist.
2
While holding in the blue button at the top of the chassis, slide the
top cover back until it stops.
3
Lift the cover straight up to remove it from the platform.
4
Ensure the CallPilot PCI riser card is secure.
5
Inspect the interior for any cables that are not seated properly.
6
Take note of any physical signs of damage. For example, check for
loose piece parts and screws in the corners of the chassis.
7
If you notice damage to any of the parts in your server, contact your
Nortel representative immediately.
—End—
To replace the server cover
When you finish inspecting the interior of your server, replace the server
cover.
Step
Action
1
Attach the ESD strap to your wrist and attach the other end to a
known grounded connection.
2
Place the cover on the server and align the cover with the chassis
tab guides.
3
Slide the top cover back until it stops.
—End—
Nortel CallPilot
600r Server Hardware Installation
NN44200-307
01.03
Standard
5.0
14 May 2008
Copyright © 2007-2008, Nortel Networks
.