Figure 3 rear panel, Table 2 rear panel – Nortel Networks Server 600r User Manual
Page 15
Server features
15
Label
Description
Label
Description
C
Critical fault LED
K
System ID LED (white)
D
Major fault LED
J
NIC activity LED (green)
E
Minor fault LED
I
Main power LED (green)
F
Power LED
H
not used
G
Disk 0 Activity/Fault LED (green/amber)
Rear panel controls and features
The following diagram shows the back panel controls and features. On the
right is the AC power supply bank. The PCI card bracket is in the middle
of the back panel, while the connectors and ports are along the bottom
and the left side.
Note: Nortel provides only AC power supply. The server works with a
DC-to-AC converter, however, you must ensure converter meets AC
requirements as specified on label of power supply cover. To access the
power supply cover, remove server cover. For more information about
the server cover, see
"To remove the server cover" (page 24)
.
Figure 3
Rear panel
Table 2
Rear panel
Label
Description
Label
Description
A
USB 0, USB 1, USB 2
(labelled 0, 1, 2 on the
server)
G
Ground studs (used with system with DC input
power supply)
B
PS/2 Mouse
H
RJ45 NIC 2 Embedded Local Area Network
(ELAN) connector for the ELAN subnet (engraved
2 on server)
C
SCSI port
I
RJ45 NIC 1 Customer Local Area Network
(CLAN) connector for Nortel server subnet
(engraved 1 on server)
Nortel CallPilot
600r Server Hardware Installation
NN44200-307
01.03
Standard
5.0
14 May 2008
Copyright © 2007-2008, Nortel Networks
.