Strapping, E1 voice module impedance strapping, Strapping -4 – Nortel Networks Passport 4400 User Manual
Page 98
T1/E1 and Digital Voice Modules
Passport 4400 Hardware Installation Manual
9-4
Strapping
E1 Voice Module Impedance Strapping
Impedance for each E1 interface line is determined by the placement of a header
on a jumper located on the E1 module. Impedance for each interface line may be
straped for either 75
Ω
or for 120
Ω.
The two lines may be strapped for the same
or for different impedance.
The locations of the two impedance straps are shown for line 1 in the following
figure.
Figure 9-6. Location of the E1 Interface Line Straps
Caution:
!
For operation in the United Kingdom, this equipment may not be
connected to an E1 Digital service using the 75
Ω
interface.
Line 1 75 ohms select.
120 ohms as shown.