beautypg.com

Configuring the power supplies, Configuring the power supplies -5 – Nortel Networks Passport 4400 User Manual

Page 109

background image

Power Supply

Passport 4400 Hardware Installation Manual

10-5

Configuring the Power Supplies

Note: The following information applies to five-slot Passport 4400 units

only (models 4450, 4450R). Three-slot units (model 4430) do not
need to be configured.

The power supply at the bottom of the stack is called the master supply. All other
supplies located above the master are called slave supplies. The five-slot models
have one master and either three (4450) or four (4450R) slave power supplies.

If adding new modules to a unit, ensure that the power supplies are properly
configured by following these procedures.

Table 10-2. Passport 4400 jumper 12 strapping for ac units

Table 10-3. Passport 4400 jumper 12 strapping for dc units

Caution:

!

Disconnect all power from the unit before performing these

procedures.

Table 10-1. Configuring the Power Supplies

For Units
Containing...

4400 with Standard
Power Supply

4400 with Redundant
Power Supply

ac Units...

dc Units...

1-3 Modules includ-
ing the base module

Unplug top power supply
(slave)

Unplug the top two pow-
er supplies (slaves)

position
jumper J12
according to
Table 10-2

position
jumper J12
according to
Table 10-3

4-5 Modules includ-
ing the base module

Plug in all four power
supplies (master + 3
slaves)

Plug in all five power
supplies (master + 4
slaves)

Passport 4400 model and
configuration

Jumper Positions (J-12)

1

2

3

4

5

6

7

8

5-slot standard, ac, 1 to 3 modules

X

X

X

X

X

X

5-slot standard, ac, 4 to 5 modules

X

X

X

X

X

5-slot redundant, ac, 1 to 3 modules

X

X

X

X

X

X

X

5-slot redundant, ac, 4 to 5 modules

X

X

X

X

X

Passport 4400 model and
configuration

Jumper Positions (J-12)

1

2

3

4

5

6

7

8

5-slot standard, dc, 1 to 3 modules

X

X

X

X

X

5-slot standard, dc, 4 to 5 modules

X

X

X

X

5-slot redundant, dc, 1 to 3 modules

X

X

X

X

X

X

5-slot redundant, dc, 4 to 5 modules

X

X

X

X