Server dimensions and weight, Environmental specifications, Front panel controls and features – Nortel Networks Server 1005r User Manual
Page 12
12
Chapter 2 1005r server description
Server dimensions and weight
Height
87.6 mm (3.45 in.)
Width
435.3 mm (17.4 in.)
Depth (distance from front to back)
508 mm (20 in.)
Weight of fully loaded system
20 kg (44 lb)
Environmental specifications
Environmental condition
Specification
Operating temperature
5
C to 35
C (41
F to 95
F)
Maximum rate of change must not
exceed 10
C (50
F) per hour.
Non operating (storage) temperature
-40
C to +70
C (-40
F to +158
F)
Non operating humidity
95% @ 23 to 40
C
Altitude
< 1 829 m (6 000 ft)
Electrostatic discharge
<= 15 kV
Acoustic noise
< 55 dBA
Handling drop (storage)
18 in free-fall (when packaged)
Handling drop
2g 11 mS
Front clearance
50.8 mm (2 in.)
Side clearance
25 mm (1 in.)
Rear clearance
92 mm (3.6 in.)
Front panel controls and features
The following diagram shows the front view of the 1005r server chassis with
the bezel cover removed. When the bezel cover is on, only the DVD and
USB connections, controls, alarm LEDs, and status LEDs are visible. With
the bezel cover removed, both hard drives, the peripheral DVD/CD/CDRW
drive, the anti-static connection, and the front serial port are accessible.
Nortel CallPilot
1005r Server Hardware Installation
NN44200-308
01.06
Standard
5.0
15 May 2008
Copyright © 2006-2008, Nortel Networks
.