Digital t1/e1 probe settings – Network Instruments GigaStor 114ff User Manual
Page 35

Configuring Observer for your WAN device
Chapter 2 Installing Your GigaStor
35
rev. 1
Digital T1/E1 Probe Settings
To access the probe settings, select the probe, right-click and choose
Probe or Device Settings. Then click the T1/E1 tab (Figure 22).
Figure 22 T1/E1 WAN Probe Settings
Table 2 describes fields in Figure 22.
Table 2 T1/E1 WAN Probe Settings
Setting
Explanation
WAN/Frame Relay Type
Choose T1 or E1 to match the type of link you are analyzing.
Encapsulation
You must set this to match the settings on the frame relay CSU/DSU.
Subprotocol
If ATM or LAPB is the selected encapsulation method, you must choose the sub-
projects on the link.
Link 1 and Link 2 Channel Settings (Note that for the link and settings to be activated, you must check the
On check box for that link).
Fractionalized
Check if this link is configured for fractionalized operation.
Channel selector check
boxes
Choose the channels you want to be included in the analysis.
Include in Util.
Thermometer.
Check if you want to include statistics from this link in the Bandwidth Utilization
Thermometer.