Paradyne 3162 DSU/CSU User Manual

Page 91

background image

Configuration Options

C-3

3162-A2-GB20-30

March 1999

Table C-1.

Network Interface Configuration Options (2 of 3)

Management Link: Disable
Enable Disable

Specifies whether Facility Data Link (FDL) is enabled. Selecting Enable allows SNMP or
Telnet traffic to flow over the
4 kbps data link provided by FDL. Running SNMP or Telnet over FDL requires an
end-to-end FDL connection and cannot be terminated within the network.

Enable – Enables the FDL management link for SNMP or Telnet.

Disable – Disables the FDL management link.

NOTES: – This configuration option is only available if the framing format is set to

ESF.

– This configuration option is not available if EDL is enabled.

– If the local DSU/CSU’s FDL is enabled, the remote DSU/CSU’s FDL

must also be enabled.

ANSI Performance Report Messages: Disable
Enable Disable

Specifies whether ANSI T1.403 compliant performance report messages (PRMs) are
generated.

Enable – Generates and sends ANSI PRMs over the FDL every second.

Disable – Prevents the DSU/CSU from generating ANSI PRMs.

NOTE:

This configuration option is only available if the framing format is set to
ESF.

Network Initiated LLB: Enable
Enable Disable

Allows initiation and termination of the LLB to be controlled by the receipt of
LLB-Actuate and LLB-Release commands from the network (or remote DSU/CSU).

Enable – Causes the DSU/CSU to enter an LLB (if the DSU/CSU can perform an LLB
in its current state) and to cause an LLB-Release command to terminate the LLB.

Disable – Causes the DSU/CSU to ignore LLB-Actuate and LLB-Release commands
(the DSU/CSU is not in compliance with ANSI T1.403 and AT&T TR 62411).

NOTE:

If this configuration option is enabled, the DSU/CSU recognizes the in-band
LLB-Actuate and LLB-Release codes specified by AT&T as well as the
bit-oriented FDL messages specified by ANSI (for ESF only).

Network Initiated PLB: Enable
Enable Disable

Allows initiation and termination of the PLB to be controlled by the receipt of
PLB-Actuate and PLB-Release commands from the network (or remote DSU/CSU).

Enable – Causes the DSU/CSU to enter a PLB (if the DSU/CSU can perform a PLB in
its current state) and to cause a PLB-Release command to terminate the PLB.

Disable – Causes the DSU/CSU to ignore PLB-Actuate and PLB-Release commands
(the DSU/CSU is not in compliance with ANSI T1.403 and AT&T TR 54016).

NOTES: – If this configuration option is enabled, the DSU/CSU recognizes the

in-band PLB-Actuate and PLB-Release codes specified by AT&T as well
as the bit-oriented FDL messages specified by ANSI.

– This configuration option is only available if the network interface

framing is set to ESF.