Paradyne 3162 DSU/CSU User Manual
Page 169
SNMP MIB Objects
E-23
3162-A2-GB20-30
March 1999
Where these object identifiers are defined as follows:
H
testLoopDTLB – OBJECT IDENTIFIER ::= [wellKnownTests 2]
H
testMonQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 3]
H
testMon511 – OBJECT IDENTIFIER ::= [wellKnownTests 4]
H
testSendQRSS – OBJECT IDENTIFIER ::= [wellKnownTests 5]
H
testSend511 – OBJECT IDENTIFIER ::= [wellKnownTests 6]
H
testSendV54Up – OBJECT IDENTIFIER ::= [wellKnownTests 7]
H
testSendV54Down – OBJECT IDENTIFIER ::= [wellKnownTests 8]
H
testSendFT1Up – OBJECT IDENTIFIER ::= [wellKnownTests 9]
H
testSendFT1Down – OBJECT IDENTIFIER ::= [wellKnownTests 10]
Generic Interface Test Table – “ifExtnsTestResult” Object
(ifExtnsTestEntry 5)
This object contains the result of the most recently requested test. Only the
following values are supported by the DSU/CSU.
H
none(1) – No test currently active.
H
inProgress(3) – A test is currently in progress.
H
notSupported(4) – The requested test is not supported.
H
unAbleToRun(5) – The requested test cannot run due to the state of the unit.
Generic Interface Test Table – “ifExtnsTestCode” Object
(ifExtnsTestEntry 6)
This object contains a code that contains more specific information on the test
result. This object is defined as an object identifier. Only the following values are
supported by the DSU/CSU.
H
none – No further information is available. Used for the send pattern/code
and loopback tests.
H
inSyncNoBitErrors – A monitor pattern (QRSS or 511) test has synchronized
on the pattern and has not detected any bit errors.
H
inSyncWithBitErrors – A monitor pattern (QRSS or 511) test has
synchronized on the pattern and has detected bit errors.
H
notInSync – A monitor pattern (QRSS or 511) test has not synchronized on
the requested pattern.