Test Jacks

Six test jacks (Figure 4-1) are located on the front panel. The DSU/CSU test jack
functions are shown in Figure 4-2 and described in

Table 4-7

. The Selectable

Test Jack branch of the asynchronous terminal menu tree (see

Appendix A

)

allows you to select either Equipment (EQPT) or Network (NET) functionality for
the Monitor test jack.

"

Procedure

To select either Equipment or Network for the Monitor test jack:

1. From the Main Menu screen, select Control.

2. From the Control screen, select Select Monitor Jack.

3. Select either EQPT (Equipment) or NET (Network) depending on the type of

Monitor test jack that you want to implement.

In

Out

In

Out

In

Out

NET

MON

EQPT

496-14808

Figure 4-1.

Test Jacks

LINE

RECEIVER

INTERNAL

CIRCUITRY

LINE

RECEIVER

TERMINAL

EQUIPMENT

(DTE)

NETWORK

NET

Out

EQPT

In

MON

Out

NET

In

EQPT

Out

MON

In

496-14875

Mon Jack: EQPT

Mon Jack: NET

Mon Jack: EQPT

Mon Jack: NET

(Selectable)

(Selectable)

Figure 4-2.

Test Jack Block Diagram