Monitoring and Testing

4-11

3162-A2-GB20-30

March 1999

Troubleshooting

The DSU/CSU is designed to provide you with trouble-free service. However,
Table 4-6 gives you some direction if a problem occurs.

For problems other than those listed in the table, please contact your service
representative.

Table 4-6.

Troubleshooting (1 of 2)

Symptom

Possible Cause

Solutions

No power

1. The power module is not

securely attached.

2. The wall receptacle has

no power.

1. Check the power module

attachment.

2. Check the wall

receptacle power by
plugging in some
equipment that is known
to be working.

Power-Up Self-Test fails

The DSU/CSU has
detected an internal
hardware failure.

Contact your service
representative.

Message

LOS at

Network

appears

1. Network cable problem.

2. No signal is being

transmitted at the
far-end.

3. Facility problem.

1. Check that the network

cable is securely
attached at both ends.

2. Check the far-end status.

3. Contact your facility

provider.

Message

LOS at DTE

appears

1. 1.DTE Drop/Insert

(DSX-1) cable problem.

2. No signal being

transmitted from the
DTE.

1. Check that the DTE

Drop/Insert (DSX-1)
cable is securely
attached at both ends.

2. Check the DTE status.

Message

OOF at

Network

appears

1. Incompatible framing

format between the
network and the
DSU/CSU.

2. Network cabling

problem.

3. Facility problem.

1. Check that the framing

format for the network
interface is correct.

2. Check that the network

cable is securely
attached at both ends.

3. Contact your facility

provider.