Configuration Option Tables

A-10

7986-A2-GB20-10

December 1998

Table A-4.

Communication Port Options (3 of 3)

Login Required (Asynchronous mode only)

Possible Settings: Enable, Disable
Default Setting: Disable

Specifies if an ID and password are required to access the asynchronous terminal
interface on the communication port. Login IDs are created with a password and access
level. Refer to

Chapter 7,

Creating a Login

.

Enable – Login ID and password are required to access the asynchronous terminal
interface.

Disable – No Login ID and password are required to access the asynchronous terminal
interface.

Port Access Level (Asynchronous mode only)

Possible Settings: Administrator, Operator
Default Setting: Administrator

Specifies the highest level of access allowed when accessing an ATI session through a
Telnet session.

Administrator – This is the higher access level, permitting full control of the 7986
Termination Unit. Access level is determined by the Login ID. If Telnet Login Required is
disabled, the session access level is Administrator.

Operator – This is the lower access level, permitting read-only access to status and
configuration screens.

Inactivity Timeout (Asynchronous mode only)

Possible Settings: Enable, Disable
Default Setting: Disable

Provides automatic logoff of a Telnet session.

Enable – The Telnet session terminates automatically after the Disconnect Time.

Disable – A Telnet session will not be closed due to inactivity.

Disconnect Time (Minutes) (Asynchronous mode only)

Possible Settings: 1 – 60
Default Setting: 5

Number of minutes of inactivity before the session terminates automatically. Timeout is
based on no keyboard activity.

H

Disconnect Time (minutes) option appears when Inactivity Timeout is enabled.

1 to 60 – The Telnet session is closed after the selected number of minutes.