beautypg.com

Standards compliance for snmp traps, Snmp traps, Warmstart – Paradyne M/HDSL Standalone Termination Unit HOTWIRE 7986 User Manual

Page 105: Authenticationfailure, Appendix b, Standards compliance for

background image

B-1

7986-A2-GB20-10

December 1998

Standards Compliance for
SNMP Traps

B

SNMP Traps

This section describes the unit’s compliance with SNMP standards and any
special operational features for the SNMP traps supported. The unit supports the
following traps:

H

warmStart

H

authenticationFailure

H

linkUp

H

linkDown

warmStart

SNMP Trap

Description

Possible Cause

warmStart

The unit has reinitialized
itself.

The trap is sent after the
unit resets and stabilizes.

There are no
variable-bindings.

H

Reset command.

H

Power disruption.

authenticationFailure

SNMP Trap

Description

Possible Cause

authenticationFailure

Failed attempts to access
the unit.

There are no
variable-bindings.

Three unsuccessful attempts
were made to enter a correct
login/password combination.