Configuration Option Tables

A-3

7986-A2-GB20-10

December 1998

Table A-1.

Network Interface Options (2 of 2)

DSL Line Rate

Possible Settings: 144, 272, 400, 528, 784, 1040, 1552, 2064
Default Setting: 2064

Specifies the DSL line rate of the unit. This option is only available when the standalone
unit is configured as an LTU and AutoRate is disabled (unit is in fixed rate).

400 – The DSL Line rate is 400.

528 – The DSL Line rate is 528.

784 – The DSL Line rate is 784.

1040 – The DSL Line rate is 1040.

1552 – The DSL Line rate is 1552.

2064 – The DSL Line rate is 2064.

NOTE:

For associated payload rates refer to Table 3-4,

Fixed Rate Payload Rates

and DSL Line Rates

in Chapter 3,

Initial Startup and Configuration.

Peer IP Address

Possible Settings: 000.000.000.000 – 223.255.255.255, Clear
Default Setting: 000.000.000.000

Specifies the peer IP address for the remote management providing the remote
management link on the DSL loop. This option is only available when the standalone
unit is configured as an LTU. The Peer IP Address is must be in the same subnet

Address Field(000.000.000.001 – 223.255.255.255) – Enter an address for the peer
unit. The range for the first byte is 000 to 223, with the exception of 127. The range for
the remaining three bytes is 000 to 255. The peer IP address must be in the same
subnet as the MCC address.

Clear – Clears the IP address field and sets to all zeros.

Circuit Identifier

Possible Settings: [ASCII Text], Clear
Default Setting: [blank]

Uniquely identifies the circuit number of the transmission vendor’s DSL line for
troubleshooting purposes.

[ASCII Text] – Enter a maximum of 128 characters. All printable ASCII characters
except ^ (caret) are allowed.

Clear – Clears the field.