Configuration Option Tables
A-18
7986-A2-GB20-10
December 1998
Table A-7.
SNMP Traps Options (2 of 2)
Enterprise Specific Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if SNMP traps are generated for enterprise-specific events.
Enable – SNMP traps are generated for
enterpriseSpecific events.
NOTE:
Standards Compliance
Disable – No enterprise-specific event traps are sent.
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.
Disable – No
linkUp or linkDown SNMP traps are generated.
Up – A
linkUp trap is generated when the 7986 Termination Unit recognizes that one of
the communication interfaces is operational.
Down – A
linkDown trap is generated when the 7986 Termination Unit recognizes a
failure in one of the communication interfaces.
Both – Sends trap messages for detection of both
linkUp and linkDown.
NOTE:
in Appendix B, Standards Compliance for
SNMP Traps.
Link Trap Interfaces
Possible Settings: Network, SYNC, All
Default Setting: All
Determines if the SNMP
linkUp, SNMP linkDown, and interface-related
enterpriseSpecific traps are generated for the network interface, synchronous data
(DTE) port, or both.
Network – SNMP trap messages are generated for the network interface.
SYNC – SNMP trap messages are generated for the synchronous data (DTE) port.
All – SNMP trap messages are generated for the network E1 interface and the
synchronous data (DTE) ports.