beautypg.com

Printronix L1024 User Manual

Page 64

background image

3–20

Configuring the Printer

Fuser Temperature

The fuser temperature option allows you to reduce the normal temperature of the

fuser by up to –20 C in 5 degree increments. This reduction can be required due

to the print media. For example, thinner material may curl or waffle at high

temperatures and adhesive material on label material may melt. It is necessary to

lower fuser temperature in such cases.

The selections on the control panel are:

Normal (this is the default selection)

–5 degrees C

–10 degrees C

–15 degrees C

–20 degrees C

Energy Timeout

The energy timeout option provides the ability to select the length of time before

the printer goes into the energy saving mode. From the energy saving mode, the

printer will require warm up time to bring the fuser to the configured

temperature. Energy is saved by turning off heater power to the fuser.

The timeout selections are:

1 minutes

5 minutes (this is the default selection)

10 minutes

30 minutes

Disabled