Printronix L1024 User Manual
Page 64
3–20
Configuring the Printer
Fuser Temperature
The fuser temperature option allows you to reduce the normal temperature of the
fuser by up to –20 C in 5 degree increments. This reduction can be required due
to the print media. For example, thinner material may curl or waffle at high
temperatures and adhesive material on label material may melt. It is necessary to
lower fuser temperature in such cases.
The selections on the control panel are:
Normal (this is the default selection)
–5 degrees C
–10 degrees C
–15 degrees C
–20 degrees C
Energy Timeout
The energy timeout option provides the ability to select the length of time before
the printer goes into the energy saving mode. From the energy saving mode, the
printer will require warm up time to bring the fuser to the configured
temperature. Energy is saved by turning off heater power to the fuser.
The timeout selections are:
1 minutes
5 minutes (this is the default selection)
10 minutes
30 minutes
Disabled