beautypg.com

Displaying serial port information – Patton electronic ONSITE 2800 User Manual

Page 53

background image

Serial port configuration task list

53

OnSite 2800 Series User Manual

4 • Serial port configuration

2800(frm-rel)[0/0]#pvc 1
2800(pvc)[1]#shutdown

Check the PVC 1 status by using

show running-config

and verify that the entry shutdown occurs in the con-

figuration part responsible for this PVC.

2800(pvc)[1]#show running-config
Running configuration:
#----------------------------------------------------------------#
#

#

# 2500

#


pvc 1
encapsulation rfc1490
bind interface wan router
shutdown
exit

Displaying serial port information

The following example shows the commands used to display serial port configuration settings.

HDLC Driver: 0x8496b8
=====================

Slot: 0
Number of Ports: 1
HDLC Driver: 0x8496b8
=====================

Slot: 0
Number of Ports: 1

Port: serial 0 0 0
------------------

State: OPENED

Configuration
Hardware Port: X.21
Port Type: DCE
CRC: CRC-16
Transmit Edge: Normal
Max Frame Length: 1920
Baudrate: 64000 bps
Recv Threshold: 1