Chapter 10 installation, Introduction, Power requirements – Printronix P3000 Series User Manual
Page 197

10–1
Installation
CHAPTER 10
INSTALLATION
Introduction
This chapter explains the P3000 Series installation procedures. Read this chapter carefully before in-
stalling and operating the printer. Perform the procedures in the order presented. The following topics
are discussed in this chapter:
•
Power Requirements
Page 10–1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
•
Site Requirements
Page 10–2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
•
Shipping Restraints
Page 10–4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
•
Cable Connections
Page 10–6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
•
Preliminary Test
Page 10–8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Requirements
A label on the back of the printer near the power cord indicates the voltage and frequency require-
ments. The printer must be connected to the specified power source in the proper range, 92 to 132 VAC
or 184 to 264 VAC, at 50 to 60 Hz. The printer automatically senses and adjusts itself to conform to the
proper voltage range. Primary circuit protection is contained in the printer. Consult an electrician if
printer operation affects local electrical lines.
IMPORTANT
Printronix recommends that printer power be supplied from a separate circuit pro-
tected at 20 amps for 120 VAC, or 10 amps for 240 VAC at 50 or 60 Hz.
WICHTIG
Es wird empfohlen, dass der Strom von einem separaten Wechselstromkreis dem
Drucker zugeführt wird, der mit 20 A für 120 V oder 10 A für 240 V geschützt ist und
50 oder 60 Hz hat.