M
INSTALLATION & CONNECTION
Drill holes (diameter 5mm, more than 35mm
deep) on the ceiling by matching to the holes
on the case bed, and insert plastic anchors
(HUD 5) fully into the holes. Fix the case bed
on the ceiling by using Tapping Screws (TH
M4xL30). (4 places)
Connect power and video cables and arrange cable running not to damage or
squeeze them, and assemble the camera unit in the reverse way.
Adjust the lens aiming to your desired direction.
Assemble the Dome Cover.
For waterproof purpose, fix and secure the bolt using L-wrench provided.
For the wall mounting installation and how to connect the alarm cables, refer to the installation
instructions of SND-5080F. (pages 26~27)
Adjusting the monitoring direction for the camera (SND-5080/SND-
5080F/SNV-5080)
You can adjust the camera direction only when the camera is fixed on the ceiling.
Then, turning the camera to the left or right is referred to as "Panning", while tilting the
angle is "Tilting". For panning, the panning limit is 220° for the clockwise, and 120° for the
counterclockwise, a total of 340° enabled; further rotation is stopped by the stopper.
3.
4.
5.
6.
M
Panning
Tilting