beautypg.com

To check the installation – Sun Microsystems 1.0 User Manual

Page 44

background image

18

SunFDDI/P 1.0 Adapter User’s GuideMay 1997

3

If Volume Manager (

vold

) is not running on your machine, unmount the

CD-ROM before you eject and remove the directory that you created:

3. Reboot your machine.

To Check the Installation

1. Use

netstat(1M)

to check for SunFDDI/P interfaces.

2. Use

ifconfig(1M)

to check the current state of the SunFDDI/P

interfaces.

3. Use

ping(1M)

to verify that you can send and receive data across the

FDDI connection.
If your SunFDDI/P station is attached to an active FDDI network, try to
access a remote station.

# /usr/sbin/umount /cdrom/sunfddip_1_0

# eject cdrom

# rmdir /cdrom/sunfddip_1_0

% /usr/bin/netstat -i

Name Mtu Net/Dest Address Ipkts Ierrs Opkts Oerrs Collis

Queue

lo0 8232 loopback localhost 21 0 21 0 0 0

le0 1500 our-lan hysop 2146 0 950 1 13 0

pf0 4352 our-fddi hysop-pf 1086 0 907 0 0 0

% /usr/sbin/ifconfig pf0

pf0

:

flags=863 mtu 4352

inet

netmask

broadcast

ether

% /usr/sbin/ping hemlock-pf

hemlock-pf is alive

SunFDDI Interface

pf

---->