Parameters

66

Security profile

You should define the

Æ Security protocol setting if the optiPoint 400 stan-

dard is connected to a HiPath 5000 system.

Three settings are available:

off (voice encryption is disabled).

reduced (voice encryption on one side only –

Æ Gatekeeper encrypts

data sent).

on (voice encryption on both sides –

Æ IP phone and Æ Gatekeeper

encrypt data sent)

Security window (seconds)

A time window is used if the IP phone is connected to a HiPath 5000 sys-
tem and

Æ Security profile is activated (reduced or on). The tool only ac-

cepts messages from the

Æ Gatekeeper that arrive within the defined

time window. The highest value you can enter here is 120 minutes.

Server type

In the list field, specify the communication system. The following options
are available:

Other

HiQ8000

Broadsoft

Sylantro

The default is Other.

Session Duration (minutes)

Enter a maximum duration in minutes for a session here.

Session Timer

Switches the SIP Session timer on and off. The timer controls the dura-
tion of a session.

Silence Suppression

The option can be enabled or disabled.

SIP Gateway Adress

Enter the

Æ IP Address of the SIP gateways if gateway mode is in use.

SIP Gateway Port

Enter the

Æ Port number for communicating with the SIP Gateway.