beautypg.com

6 connectors for fiber-optic cables – Siemens X-400 User Manual

Page 99

background image

Installation and Commissioning

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03

99

6.6.6 Connectors for Fiber-Optic Cables

Gigabit Transmission with FOC

Data transmission at 1 Gbps is over multimode FOC or single mode FOC. In both
cases, the fiber-optic cable is plugged into the SC duplex socket with the SC du-
plex plug. The connectors have polarity reversal protection mechanisms.

When a media module is inserted, port 1 is to the front and port 2 to the rear.

Notice
Fiber-optic cable connectors are susceptible to contamination and mechanical
damage to the face. Protect open connections with the supplied dust caps.

Figure 6-18

SC Duplex plug with gigabit media module MM492-2LD