Product Description of SCALANCE X-400

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

40

C79000-G8976-C186-03

Signaling Contact

The following can be signaled over a floating signaling contact:

Failure of the power supply.

The power supply monitored is selected in the fault mask.

Bad link status of a port.

(wrong connector or no connection to partner device). The port monitored is se-
lected in the fault mask.

Change to the DIL switch during operation.

Possible inconsistency between the switch setting and the actual operating
state, The switch setting is adopted only after a restart.

If the SCALANCE X414-3E is set as the redundancy manager, the following errors
are also reported:

● Bad link status of the ring ports, regardless of the status of the fault mask.

● Configuration of a second SCALANCE X414-3E as redundancy manager in the

same ring.