beautypg.com

Siemens X-400 User Manual

Page 91

background image

Installation and Commissioning

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03

91

6.6.2 Connectors of the Signaling Contact and Grounding Strap (X2)

The signaling contact is connected by contacts MK1 and MK2 on the 4-pin connec-
tor to the rear terminal block on the PS module.

X 2

X 1

M K 2

G N D

M 3

M K 1

Figure 6-10

Pin assignment of connector X2

By inserting a strap between protective earth P and M3, the SCALANCE X414-3E
switch can be operated with grounded reference potential.

When the device ships, no strap is fitted (non-grounded reference potential).

Conn. 2

MK1

Floating signaling contact relay connector 1

M3

Ground

GND

Protective

earth

MK2

Floating signaling contact relay connector 2