beautypg.com

5 connectors for the twisted pair cables – Siemens X-400 User Manual

Page 94

background image

Installation and Commissioning

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches

94

C79000-G8976-C186-03

6.6.5 Connectors for the Twisted Pair Cables

The FastConnect Cabling System

With the IE FC RJ-45 Plug and the FastConnect cables (FC), you can achieve a
segment length up to 100 m without patching. In this case, the IE FC standard ca-
ble 2x2 is connected directly to the SCALANCE X414-3E and other components
on the network.

Two FastConnect cable types are available, the eight-wire IE FC standard cable
4x2 and the four-wire IE FC standard cable 2x2.

The diameter of the IE FC standard cable 4x2 does not allow connection to an RJ-
45 plug so that only the IE FC standard cable 2x2 as a four-wire cable is suitable
for RJ-45 plugs. This means that the maximum transmission rate is 100 Mbps.

The flexible eight-wire patch cable (TP cord) for gigabit transmission allows a maxi-
mum cable length of 10 m.

X 2 0 8

S 7 - 4 0 0

X 4 1 4 - 3 E

B

A

B

B

B

P C

A = 1 0 m

B = 1 0 0 m

Figure 6-13

FastConnect Cabling

A

TP cord (1 Gbps)

B

IE FC Standard Cable 2x2 (100 Mbps)