beautypg.com

Siemens X-400 User Manual

Page 69

background image

Installation and Commissioning

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03

69

Figure 6-1

Installation on an S7-300 rail

Removing from the S7-300 rail

To remove the device, you require a slotted screwdriver with a 5.5 mm wide blade.

Notice
When removing the SCALANCE X414-3E, hold it by the backplane and not by the
modules, otherwise the device may be damaged.

To remove the device, follow the steps below:

1. Remove the covers from slots 7 and 9 (see section 6.2.2) and the dummy

cover from slot 8 (see section 6.2.3). If media modules are inserted, remove
the fast Ethernet media module instead of the cover from slot 7 (see section
6.2.1).

2. Using a screwdriver with a 5.5 mm wide blade, loosen the two captive screws

in the backplane at slot 7 and between slots 8 and 9.

3. Pull out the lower part of the basic device slightly towards the front and lift it

from the S7-300 rail.