beautypg.com

Siemens X-400 User Manual

Page 43

background image

Product Description of SCALANCE X-400

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03

43

Serial Port

The Switch CPU of the SCALANCE X414-3E has an RS-232 port. This is used for
the following purposes:

● Firmware updates

● Management with the aid of the command interpreter (Command Line Inter-

preter, CLI) including setting of the IP address information.

Input to the command interpreter is over command lines.

For more detailed information, refer to the SCALANCE X-400 Configuration Man-
ual

.

P i n 1
P i n 2 R D
P i n 3 T D

P i n 5 S G

P i n 4

P i n 6

P i n 7
P i n 8
P i n 9

Figure 3-8

Pin assignment

Ethernet Port

On the bottom panel of the SCALANCE X414-3E , there is an 8-pin RJ-45 jack.
This Ethernet interface can be used for productive communication with other
switches or end devices. This is used for the following purposes:

● Configuration

● Commissioning

The SCALANCE X414-3E can be configured either locally or over a network.

For more detailed information, refer to the SCALANCE X-400 Configuration Man-
ual

.