beautypg.com

Siemens X-400 User Manual

Page 37

background image

Product Description of SCALANCE X-400

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03

37

The modules in the individual slots have the following function (slot 1 is reserved
for a power supply unit):

Slot 2

Power module
The input voltage of 24 V DC is transformed to the internal supply voltage. The
module has two 4-pin sockets for connecting a redundant power supply and for
connecting the signaling contact and protective earth.

Slot 3

Digital input module
The input module has two 5-pin sockets for connecting eight digital inputs that
allow different signaling modes.

Slot 4

CPU module
- Contains the processor that provides the management functionality.
- C-PLUG for storage of parameter assignment.
- DIL switch for the redundancy manager function and to specify the ring

ports.

- SELECT/SEL button for switching over the display modes, for resetting to

the factory default settings and to define the fault mask.

- LED display of the display modes DMode A through DMode D.

Slot 5

Contains two RJ-45 jacks allowing attachment of electrical (twisted pair) con-
nections (10, 100, 1000 Mbps).
As an option, slot 5 allows the use of an optical gigabit module with two ports
(1000Base-SX or 1000Base-LX).

Slots 6 and 7

Optional use of two optical fast Ethernet modules (100 Mbps) each with two
ports (100Base-FX).

Slot 8

No function in system.

Slot 9 through 11

Each contains four RJ-45 jacks allowing attachment of 12 electrical (twisted
pair) connections in total (10, 100 Mbps).
These cannot be used by media modules.