Installation and Commissioning
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03
97
The maximum segment length of 100 m also applies when using the FastConnect
cabling with TP cord. Normally, FastConnect cable with a length of 90 m is used.
The remaining 10 m is then available for TP cord at both ends (total of 10 m).
A 1 + A 2 = 1 0 m
A 1 + B + A 2 = 1 0 0 m
X 2 0 8
B
S 7 - 4 0 0
X 4 1 4 - 3 E
A 1
A 1
A 1
A 2
A 2
A 2
I E F C R J 4 5 M o d u l a r
O u t l e t I n s e r t 1 G E
I E F C R J 4 5
M o d u l a r
O u t l e t I n s e r t
1 G E
I E F C R J 4 5
M o d u l a r
O u t l e t I n s e r t
2 F E
I E F C R J 4 5 M o d u l a r
O u t l e t I n s e r t 2 F E
B
B
B
A 2
X 4 1 4 - 3 E
Figure 6-16
FastConnect Cabling
A1
TP Cord 4x2
A2
TP Cord 4x2
B
IE FC Standard Cable 4x2