beautypg.com

4 led display - di module – Siemens X-400 User Manual

Page 111

background image

Installation and Commissioning

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
C79000-G8976-C186-03

111

6.8.4 LED Display - DI Module

LED Display of the Digital Inputs 1 through 8

The status of four digital inputs (IN1 through IN4 or IN5 through IN8) can be indi-
cated by the four LEDs on the front panel of the DI module.

F

L 1

L 2

P o w e r M o d u l e L E D s

P o r t - L E D s

P 1

P 2

C P U - L E D s

R M

S T B Y

D M 1

D M 2

D I - L E D s

I N 1 / I N 5

I N 2 / I N 6

I N 3 / I N 7

I N 4 / I N 8

Figure 6-27

LEDs of the digital inputs and display modes

Four modes (display mode A through D) are available and these are displayed by
two LEDs (DM1, DM2) on the Switch CPU. The display modes A and C are identi-
cal as are modes B and D.

Mode DM1

DM2 IN1/5 IN2/6 IN3/7 IN4/8 Meaning

DMode A
DMode C

off off Digital

inputs

IN1 through IN4

on

Signal at input IN1

on

Signal at input IN2

on

Signal

at

input

IN3

on

Signal at input IN4

Mode

DM1 DM2 IN1/5 IN2/6 IN3/7 IN4/8 Meaning

DMode B
DMode D

on off Digital

inputs

IN5 through IN8

on

Signal

at

input

IN5

on

Signal

at

input

IN6

on

Signal

at

input

IN7

on

Signal

at

input

IN8