GATEWAY UNIT

EX500 SERIES

COM A

COM B

COM C

COM D

LAN

NS

MS

100

LINK

PWR

18

19

Display/Switch Setting

Display

NOTE
When connecting manifold valve only without connecting Input unit manifold, LEDs of
COM A to D do not light. To make them light, connect a terminal plug to the unused
connector of SI unit ( "C1" or "0" ).

Switch setting

Open the station number switch protective cover and set the switches with a
sharp-pointed watchmakers screwdriver etc.

NOTE
1. Be sure to turn off the power before setting the switches.
2. Be sure to set these switches before use.
3. After opening and closing the station number switch protective cover, tighten the

screws by proper tightening torque. ( Tightening torque : 0.6N m )

Display

Content

PWR

Off

The power supply for solenoids lowering

Green lights up

The power supply for solenoids normal

LINK

Off

The power supply off/initialized

Green lights up

Ethernet communication established

Green flashes

Data sent/received

100

Off

Communication at 10Mbps

Green lights up

Communication at 100Mbps

MS

Off

The power supply off

Green lights up

Operating normally

Green flashes

Setting error

Red flashes

Recoverable internal error

Red lights up

Unrecoverable internal error

NS

Off

The power supply off/IP address not set

Green flashes

EtherNet/IP-level communication not established

Green lights up

Multiple EtherNet/IP-level communications established

Red flashes

Multiple EtherNet/IP-level communications time out

Red lights up

IP address duplicated

COM A

Off

No input data

Green lights up

Input data received

COM B

Off

No input data

Green lights up

Input data received

COM C

Off

No input data

Green lights up

Input data received

COM D

Off

No input data

Green lights up

Input data received

1

2

3

4

5

6

7

8

1

2

3

4

5

6

SW1

SW2

ON

1

0

IP address

192.168.0.X

1

0

1

0

1

0

1

2

0

0

1

1

1

1

3

0

0

0

0

1

1

4

0

0

0

0

1

1

5

0

0

0

0

1

1

6

0

0

0

0

1

1

7

0

0

0

0

1

1

8

0

0

0

0

1

1

X

Remote control *

1

1
2

3

254

DHCP mode *

2

SW1

Reserved area
Set it to off

3

0

1

1

1

1

1

4

-

-

0

1

-

-

5

-

-

-

-

0

1

SW2

Item

Communication

setting

Communication

speed

Communication

method

Content

AUTO : The communication setting is automatically
selected.

MANUAL : The communication setting follows
the setting result by the switch No. 4 and 5.

Communicated at 10Mbps

Communicated at 100Mbps

Communicated at half duplex

Communicated at full duplex

Communication

setting

CLR/HOLD

SW2

6

0

1

Content

The output signal is cleared when the communication error occurs.

The output signal is held when the communication error occurs.

Manual set up
of IP address *

3